• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0413
806f0413-3101ffff
806f0413-3102ffff
Type
Error Message
Error
PCI express bus
X, (PCI Slot X) PCI
parity error [Note:
X = 1,2]
Action
required firmware
updates.
4. If problem persists,
remove the Adapter
Card. If system
reboots successfully
without the adapter,
replace the card.
5. (Trained technician
only) If the problem
continues, replace the
processor (see
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
1. Check the operating
system event log and
the system event log
as it may contain
additional information
(see "Event logs" on
page 79).
2. Reseat the blade
server in the
BladeCenter (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a
BladeCenter unit" on
page 39).
3. Update the device
drivers for any
expansion cards that
are installed into the
blade server.
4. Reseat the expansion
card (see "Removing
an I/O expansion
card" on page 50 and
"Installing an I/O
.
163
Chapter 5
Diagnostics