Diagnostic
Message
code
S.68005
[S.68005] An error has
been detected by the IIO
core logic on Bus %.
The Global Fatal Error
Status register contains
%. The Global Non-
Fatal Error Status
register contains %.
Please check error logs
for the presence of
additional downstream
device error data.
S.680B8
[S.680B8] Internal QPI
Link Failure Detected.
S.680B9
[S.680B9] External QPI
Link Failure Detected.
Description
Critical IOH-PCI Error.
Internal QPI Link Failure
Detected.
External QPI Link Failure
Detected.
Action
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Reseat the expansion cards (see "Removing
an I/O expansion card" on page 50 and
"Installing an I/O expansion card" on page
53).
3. Replace the following components one at a
time in the order shown, restarting the server
each time:
• Expansion cards (see "Removing an I/O
expansion card" on page 50 and
"Installing an I/O expansion card" on page
53).
• (Trained technician only) Replace the
system board (see "Removing the system-
board assembly" on page 71 and
"Installing the system-board assembly" on
page 71).
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Inspect the microprocessor socket for
foreign material, if the microprocessor socket
contains any foreign material, remove the
foreign material. If it is found damaged,
(trained technician only) replace the system
board (see "Removing the system-board
assembly" on page 71 and "Installing the
system-board assembly" on page 71).
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Inspect the microprocessor socket for
foreign material, if the microprocessor socket
contains any foreign material, remove the
foreign material. If it is found damaged,
(trained technician only) replace the system
board (see "Removing the system-board
assembly" on page 71 and "Installing the
system-board assembly" on page 71).