Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 116

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Diagnostic
Message
code
W.305000-
[W.305000A] An invalid
A
date and time have been
detected.
S.3058004
[S.3058004] A Three
Strike boot failure has
occurred. The system
has booted with default
UEFI settings.
W.3058009
[W.3058009] Driver
health protocol: missing
configuration. Requires
change settings From
F1.
100
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Description
RTC Date and Time
Incorrect.
POST failure has
occurred! System
booted with default
settings.
DRIVER HEALTH
PROTOCOL: Missing
Configuration. Requires
Change Settings From
F1.
Action
1. Run the Setup utility (see "Using the Setup
utility" on page 11). Select Load Default
Settings and save the settings.
2. Reseat the battery (see "Removing the
battery" on page 41 and "Installing the
battery" on page 42).
3. Replace the battery (see "Removing the
battery" on page 41 and "Installing the
battery" on page 42).
1. Undo any recent system changes, such as
new settings or newly installed devices.
2. Make sure that the server is attached to a
reliable power source.
3. Remove all hardware that is not supported
by the server (see http://www.ibm.com
/systems/info/x86servers/ serverproven/
compat/us/).
4. Update the firmware to the latest level (see
"Updating firmware and device drivers" on
page 23 for more information).
5. Make sure that the operating system is not
corrupted.
6. Run the Setup utility, save the configuration,
and then restart the server.
7. (Trained technician only) If the problem
remains, replace the system board (see
"Removing the system-board assembly" on
page 71 and "Installing the system-board
assembly" on page 71).
1. Select System Settings → Settings → Driver
Health Status List and find a driver/
controller reporting configuration required
status.
2. Search for the driver menu from System
Settings and change the settings
appropriately.
3. Save the settings and restart the system.