Modem Information - Comtech EF Data CDM-625A Installation And Operation Manual

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Serial-based Remote Product Management
8.5.6

Modem Information

Command
Number of
Parameter
(Instruction
Arguments
& Qualifier)
Hardware
N/A
4 bytes
Revision
Software
N/A
5 bytes
Revision
Firmware
N/A
256 bytes
Information
Serial Number
N/A
9 bytes
Fractional CnC
N/A
7 bytes
90-day Counter
Modem
N/A
8 bytes
Operational Full
Year Counter
Software
N/A
38 bytes
Revision 2
Description of Arguments
Query only.
Returns hardware revision level of both main circuit cards in the form xx.y, where:
xx indicates the main (bottom) card;
y indicates the top (modem) card.
Query only.
Returns the installed firmware version number, in the form x.x.x, where:
EXAMPLE: <0/SWR? >0/SWR=2.0.2
Query only.
Returns the installed firmware information.
NOTE: <0/FRW?B requests boot code information.
EXAMPLE: FRW=Boot: FW-0020732-,1.1.1,01/08/13
Otherwise, FRW returns firmware information for Image 1 or 2:
EXAMPLE:
<0/FRW?
>0/FRW=1:FW-0020731E,1.3.1L,07/10/14
FW-0020733C,1.3.1L,07/10/14
FW/12867AG ,2.3.3,28/07/14
FW/12868L ,2.3.1,15/04/13
FW-0020735B,1.3.1,11/09/14
FW/12874C ,1.6.0,15/08/11
FW-0020734D ,1.3.1,07/10/14
FW-0020739-,1.1.1,24/07/13
FW-0000516-,1.1.1,19/01/11
FW-0020740v,1.1.v,06/08/14
Query only.
Returns the modem 9-digit serial number.
EXAMPLE: <0/SNO? >0/SNO=176500143
Query Only.
Returns the number of seconds that Fractional CnC license has been used in the 1-year period since the last reset of the
CnC counter to 0.
EXAMPLE: <0/FCC? >0/FCC=0000455 (indicating 455 seconds)
Query Only.
Returns the number of seconds that the unit has been powered on since the last reset of the CnC counter.
The counter resets to 0 when it reaches 31536000 seconds (seconds in 365 days).
EXAMPLE: <0/FCF? >0/FCF=00001342 (indicating 1342 seconds)
Query only.
Returns the installed firmware version numbers in the Boot, Image 1, and Image 2 slots.
EXAMPLE: <0/SW2? >0/SW2=Boot:2.1.1 Bulk1*:2.1.2 Bulk2 :2.1.1
The current active image is indicated with an asterisk.
8–49
MN-CDM625A
Revision 4
Query
Response to
(Instruction &
Response to Query
Command
Qualifier)
N/A
HRV?
HRV=xx.y
(see Description of
Arguments)
N/A
SWR?
SWR=x.x.x
(see description
of arguments)
N/A
FRW?B
FRW=xxx...xxx
FRW?1
(see Description of
FRW?2
Arguments)
N/A
SNO?
SNO=xxxxxxxxx
(see Description of
Arguments)
N/A
FCC?
FCC=xxxxxxx
(see Description of
Arguments)
N/A
FCF?
FCF=xxxxxxxx
(see Description of
Arguments)
N/A
SW2?
SW2=x
(see Description
of Arguments)

Advertisement

Table of Contents
loading

Table of Contents