Pe Sensor; Holder, Detector, Pe Removal - Epson Stylus Pro 4400 Service Manual

Hide thumbs Also See for Stylus Pro 4400:
Table of Contents

Advertisement

EPSON Stylus Pro 4400/4450/4800/4880/4880C

4.2.9.5 PE Sensor

1.
Remove "Release Unit" (p343).
2. As seen from the printer rear surface, release the two left "Extension
Spring, 8.08"s from hooks on the frame.
3. Peel off acetate tape securing the FFC.
When performing the following step, be careful not to
C A U T I O N
scratch the FFC with the screwdriver.
4. Remove the screw securing "Holder, Detector, PE".
(Refer to Figure 4-213.)
C.B.S. 3x6:
1 pc.
5. Slide "Holder, Detector, PE" to the rear side, release the two hooks of the
"Holder, Detector, PE" from the two frame notches and then remove
"Holder, Detector, PE" from the frame.
Disassembly & Assembly
(Refer to Figure 4-213.)
(Refer to Figure 4-213.)
(Refer to Figure 4-214.)
Disassembly Procedures
Extension Spring, 8.08
Acetate Tape
C.B.S. 3x6
Figure 4-213. Holder, Detector, PE Removal_1
Holder, Detector, PE
Figure 4-214. Holder, Detector, PE Removal_2
Revision C
Hooks
Extension Spring, 8.08
352

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents