Epson Stylus Pro 4400 Service Manual page 184

Hide thumbs Also See for Stylus Pro 4400:
Table of Contents

Advertisement

EPSON Stylus Pro 4400/4450/4800/4880/4880C
SERVICE REQ. 00010012
Error meaning:
CR overload (high sensitivity) error
Explanation
PWM has been being output for a certain period of time. This can be made
when load on the CR Motor is slightly increased.
Remedy / Points to be checked
1. Check the load on the CR Motor.
Running load of CR Motor (check by manual operation)
Measure the resistance value of the PF Motor.
If the CR Motor is found in short mode, replace the BOARD ASSY.,
MAIN at the same time.
Damage to or wear in the CR Driven Pulley
Damaged or worn bearing of the Carriage Unit
Flaws in the CR Rail caused by roller running
Tension of the CR timing belt
2. Replace the
Motor Assy., CR (p.270)
3. Replace the
C593 MAIN Board (p.226)
Troubleshooting
SERVICE REQ. 00010013
Error meaning:
PF overload (high sensitivity) error
Explanation
PWM has been being output for a certain period of time. This can be made
when load on the PF Motor is slightly increased.
Remedy / Points to be checked
1. Check the load on the PF Motor.
2. Replace the
3. Replace the
Troubleshooting Based on Panel Messages
Measure the resistance value of the PF Motor.
If the PF Motor is found in short mode, replace the BOARD ASSY.,
MAIN at the same time.
Running load of PF Motor (check by manual operation)
Rotation load of PF Motor
Motor Assy., PF (p.349)
C593 MAIN Board (p.226)
Revision C
184

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents