4.2.5.17 PE Sensor Removal

1. Remove "Paper Guide Upper Unit". (Refer to section 4.2.5.12)
2. Remove "Tension Spring,1.2", which is installed between "Lever,
Release" and "Frame, Main, Rear".
3. Remove 2 CBP screws(3x8) securing "Lever, Assembly, Release, Cam"
to "Paper Guide Upper Unit".
4. Remove 2 "Bush, Release, Cam" from both left and right sides, and
remove "Lever, Assembly, Release, Cam". (Refer to Figure4-61)
5. Pick up 2 hooks securing "PE Sensor" to the frame, and remove "PE
Sensor". (Refer to Figure4-62)
Rev. A
"Frame, Main, Rear"
"Tension Spring,1.2"
"Lever Assembly,
Release, Cam"
"Bush, Release, Cam"
Figure 4-61. "Tension Spring,1.2", and "Lever Assembly, Release,
Cam" Removal
Hooks
PE Sensor
Figure 4-62. PE Sensor Removal