Set-Up and Operation
Perform the following steps to set up and operate the
monitor.
1. Place the monitor on a flat surface near the
computer and near an AC power outlet. Be cer
tain that the ventilation slots in the cabinet are
not blocked.
2. Connect the video input cable from the monitor
to the computer.
3. Plug the power cord into the monitor and then
into an AC outlet. Make sure the voltage selec
tion switch on the rear panel is set to the proper
position.
WARNING
Removing or lifting the ground from the AC
power source may present a potentially
lethal shock hazard. Do not use an AC two
to-three wire adapter plug with this unit.
4. Turn on the computer and the monitor. The front
panel power indicator should light.
5. Boot an operating system.
6. When a message is displayed on the monitor,
adjust the brightness and contrast controls to
obtain a comfortable display.
Initial Tests
To assess the monitor's operation, perform the color
bar test and the fill screen test. Both tests are
ROM-based.
Color Bar Test
The color bar test displays an array of colors in the
form of a bar graph. To display the color bars using a
Zenith Data Systems PC-compatible computer:
1. Press the
CTRL, AL T,
and
INS
keys in sequence,
hold them, and then release them.
2. After the Monitor prompt appears, type C and
then press
RETURN.
Color bars should now be
displayed.
Fill Screen Test
The ROM-based keyboard test can be used to set
the brightness, contrast, dimensions, focus, conver
gence, and other qualities of the display to comfort
able levels. To perform the fill screen test using a
Zenith Data Systems PC-compatible computer:
1. Press the
CTRL, ALT,
and
INS
keys in sequence,
hold them, and then release them.
2. After the prompt appears on the monitor, type
TEST and press
RETURN.
3. Select the keyboard test by pressing the 2 key.
4. Press any displayable key to fill the screen with
that character. (The capital Z is a good charac
ter to display for assessing display characteris
tics.)
Installation