Connect Water Supply Lines

c. Install 1/4-inch IPS water supply lines to match the 1/4-inch com-
pression fittings mounted on the rear of the SteamCraft 3.1. If larger
lines are used, a pressure regulator must be installed in the supply line to
maintain the pressure specified in step 2.
d. Install a manual water valve between the main cold water supply line
and the SteamCraft 3.1 lines.
e. The National Sanitation Foundation (NSF) requires installation of a
check-valve in all supply lines in accordance with and as required by
local plumbing codes.
f. At the points indicated in the recommended plumbing layouts, install a
40-mesh water strainer of the type and construction illustrated in Figure
2-20, Cleveland Range part number 102383.
4. Construct all supply lines up to the point of installing the strainer(s)
illustrated in the recommended plumbing layouts. Flush the water supply
lines before connecting the strainer(s).
• If the remaining water supply lines and/or SteamerGard are not
immediately installed and connected after flushing, temporarily cap the
water supply lines.
• If the final installation and connections are performed immediately, refer
to the connection instructions in the SteamerGard manual, and Connect
Water Supply Lines, on page 20.
The water supply connections are located at the rear of the SteamCraft 3.1, as
shown in Figure 2-21. Connect the water supply lines to the SteamCraft 3.1
by following both the general connection requirements and those
requirements specific to the type of supply system, either untreated water
supply (Figure 2-18) or water supply treatment system (Figure 2-19).