Yearly Maintenance - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

YEARLY MAINTENANCE

Figure 4-2. Water Strainer Assembly
21. BIowdown the steam generator by pressing the POWER switch to OFF.
22. After the steam generator has drained, flush it once more by pressing the
POWER switch ON, waiting for the steam generator to fill (about 3-4
minutes), and then pressing the POWER switch to OFF.
23. After the steam generator has drained, the SteamCraft 3.1 is ready for
operation as desired.
NOTE: Contact service representative or manufacturer for descaling kits or
for information on descaling procedures.
Clean Water Line Strainer
NOTE: If water quality does not meet the standards of Table 2-2 on page 7
and a SteamerGard has not been installed, the strainer may need to
be cleaned more frequently than once a year. When the steamer is
first installed, check the strainer more frequently to find out how
often it must be cleaned.
Clean the water line strainer at least once a year as follows:
1. Close the valve(s) in the steamer water supply Iine(s).
2. Unscrew the filter cap from the bottom of the strainer. Refer to Figure 4-
2.
3. Remove the filter screen and wash it with clean water.
4. Check the 0-ring for wear and replace it if necessary.
5. Put screen back into cap and replace the cap in the strainer.
6. Open water supply valve(s) and check for water leaks.
Model 21 -CET-6
ServiceManual
Page 59
Printed 12/90

Hide quick links: