Key Pad Control Panel Summary - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

KEY PAD CONTROL PANEL SUMMARY

Figure 3-1. Key Pad Control Panel
Press switches with finger tips only. Do not use kitchen
utensils or anything sharp to operate the switches.
1.
TIMER Display
This four-digit display indicates the minutes and seconds remaining in the count
down. The display reads from zero (00:00) to 99 minutes and 99 seconds (99^9). It
reads pause (PAUS) when the count down is halted either by the START/STOP
key or by the temperature compensating circuit
2. Number Pad Keys
These keys set the number of minutes and seconds in the timer count down.
Pressing the number keys 12 3 4 in this sequence, sets the timer for 12 minutes
and 34 seconds (1234).
3. START/STOP Key
This key starts and stops the timer. In TIMED mode the steaming functions are
linked to the timer. In MANUAL mode, the steaming functions are independent
of the timer.
4. CLEAR Key
This key resets the timer to zero (00:00), after it has been stopped. The timer
must be zeroed by pressing this key before a new time can beset
5. TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the manual or timed operating mode.
• Pressing the MANUAL (bottom) end of the switch selects the manual mode.
• Pressing the TIMED (top) end of the switch selects the timed mode.
6. ON/OFF switch
The ON/OFF switch controls electric power to the control panel.
• Pressing the ON (top) end of the switch energizes the steamer control panel.
A red indicator on the switch lights, and water fills the steam generator.
• Pressing the OFF (bottom) end of the ON/OFF switch turns the steamer
control panel OFF. The red indicator goes out, and the 3-minute blowdown
cycle starts.
Model 21-CET-8 Service Manual
CAUTION
Printed 12/90
Page 31