Install Water Supply Lines - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

Page 18
Model 21 -CET-8 Service Manual

Install Water Supply Lines

2. Mechanically secure the flexible conduit to the electrical access hole
(Figure 2-17).
3. The terminal block and ground connection are near the center of the side
opening.
4. Refer to the connection diagrams in Figure 2-17, and connect the wires to
the terminal block and ground connector accordingly.
5. The steamer must be electrically grounded by the installer.
6. If no further work inside the side panel is required at this time, such as
plumbing and leak checks, secure the side panel with the two mounting
screws (Figure 2-16).
Furnishing and plumbing the water supply lines is the responsibility of the
owner and/or installer. This section illustrates plumbing layouts
recommended by Cleveland Range. When installing water supply lines,
observe the following instructions.
1. Always connect a cold water supply to the SteamCraft 3.l water supply
lines. DO NOT USE HOT WATER. The steamer will not function property
or within design safety limits if hot or warm water is supplied to cither the
condenser connection or the steam generator fill connection.
2. Supply water must have a minimum dynamic pressure of 35 psi
(2-4 kg/cm) and a maximum static pressure of 60 psi (4.1 kg/cm
pressure exceeds 60 psi, a pressure regulator must be installed in the
supply lines. For best results, set the regulator for 50 psi dynamic
pressure. Water pressure greater than 60 psi will cause damage to the
solenoid valves. Local water pressure can be 100 psi or more. If possible,
check supply pressure at non-peak demand time. A local water company
can assist in this check.
3. Refer to the recommended plumbing layouts in Figures 2-18 and 2-19, and
install the water supply lines and fittings in accordance with all local and
national codes. Pay particular attention to the following requirements and
recommendations.
2
). If static
Printed 12/90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents