Cleveland Floor Type Gas Convection Steamer 24CGA10.2 Parts Manual

Cleveland Floor Type Gas Convection Steamer 24CGA10.2 Parts Manual

Floor type gas convection steamer
Hide thumbs Also See for Floor Type Gas Convection Steamer 24CGA10.2:

Advertisement

Quick Links

Parts Manual
Floor type Gas Convection Steamer
Series: SteamCraft Model 24CGA10.2
th
1333 East 179
Street
Cleveland, Ohio 44110
Phone: (216) 481-4900
1-800-338-2204
Fax: (216) 481-3782
www.clevelandrange.com

Advertisement

loading

Summary of Contents for Cleveland Floor Type Gas Convection Steamer 24CGA10.2

  • Page 1 Parts Manual Floor type Gas Convection Steamer Series: SteamCraft Model 24CGA10.2 1333 East 179 Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com...
  • Page 10 Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service. Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document.
  • Page 11 Approvals: CSA (AGA, CSA) and U.L/NSF#4 Compartment Steam Shut-Off Switch (SCS) Options & Accessories Electronic Timer with Compensating Feature (ETC) On/Off Steam Switch Controls, no timer (MC) Cleveland Range Inc. MODEL: ITEM NUMBER __________________________________________ JOB NAME / NUMBER __________________________________ Short Form Specifications...
  • Page 12: Water Quality Requirements

    Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
  • Page 13: Mechanical Timer

    CLEVELAND RANGE GEMINI 24CGA 6.2 Starting with the timed manual switch in the timed position, and no time on the timer. 1. To turn the unit on, turn the ON/OFF lever clockwise to the ON position • This mechanically closes the drain.
  • Page 14 • The fan prover switch makes allowing 24 VAC to the normally open R2 contacts. • The normally open R2 contacts close and 24 VAC is sent to the main coil of the gas valve. • The main burner is ignited and the water heated to steam. •...
  • Page 16 LT BLU C NO 11-1 11-6 PS-7 PS-7 PS-5 PS-6 PS-3 PS-1 WHT/BRN PS-2 WHT/RED 11-2 WHT/RED 2-13 2-12 2-11 2-10 GEMINI GAS / MECHANICAL TIMER PV/MV WHT/ORN 11-5 SPARK WHT/ORN 24V (GND) GND (BNR) MV/PV WHT/ORN WHT/ORN 3-12 3-11 HEAT FILL H LT BLU...
  • Page 18 PAUSE 11-1 PS-7 PS-5 PS-2 WHT/RED PS-3 PS-7 11-4 WHT/RED 2-13 2-12 2-11 2-10 GEMINI GAS / ELECTRONIC TIMER PV/MV WHT/ORN SPARK WHT/ORN 24V (GND) GND (BNR) MV/PV WHT/ORN WHT/ORN HEAT FILL LT BLU WHT/RED NOTES: 1. UPPER COMPARTMENT CIRCUIT SHOWN DUPLICATE FOR LOWER COMMPARTMENT.
  • Page 19 PROBLEM: 24CGA6 24CGA10.2 Steamer won't steam with handle in on position Steamer won't fill. Steamer won't ignite Is there power to Replace the the Timed/Manual wiring to the switch? switch Is there power Replace the from the Timed/ switch Manual switch? Does the steamer steam with the door switch...
  • Page 20 PROBLEM: 24CGA6 24CGA10.2 Steamer won't fill with the handle in the on position Adjust or replace the on/ off micro switch Replace the fill solenoid. Clean or replace the drain valve. Steamer won't fill Is there power power to the to the steamer? Is there water to the steamer?
  • Page 21 PROBLEM: Steam generator 24CGA6 won't ignite 24CGA10.2 Steamer won't ignite Steamer won't fill Is there 120 VAC between Heat and N Clean or terminals on the water replace the level board with a probe assy. jumper between terminal XL and C? Replace water level board.
  • Page 22 Electronic timer displays "PAUS" and won't count down thermo-switch START Supply cold water (35-60 Is COLD water PSI) to the supplied to the steamer. steamer? Is the door gasket Is the door out of physically alignment? damaged? Turn over the Replace the gasket or door bearings...
  • Page 23 Descaling Procedure-SteamCraft Ultra and Gemini Series How Much DISSOLVE to Use Model Dissolve Ultra 3 1/2 Gallon Ultra 5 1 Gallon 1 Gallon (ea.) Ultra 10 (Elec.) Ultra 10 (Gas) 1½ Gallon 1 Gallon (ea.) Gemini 6 & 10 1. Turn the unit OFF and open the doors: This will drain and rinse the generator for about 3 minutes.