Connect Electrical Line

5. There should be a sufficient length of flexible conduit between the
SteamCraft 3.1 connector and the wall so the unit can be moved for
service.
6. Each steamer must be electrically grounded by the installer.
7. The characteristics of the electric power supply must match the power
requirements specified on the SteamCraft 3.1 product identification
plate. The plate is located on the back of the unit (refer to Figure 2-2).
Table 2-3. Minimum Wire Requirements
VOLTS
KILO-
AMPS 1
WATTS
Phase
208
8.5
40.9
220
7.22
32.8
240
8.5
35.4
440
7.22
480
8.5
380
8.5
415
8.5
*Use solid copper wire rated for 75°C, wet location-
Connect the electrical lines to the terminal block inside the right side cover
as described below.
1. Remove the side panel by removing two screws (Figure 2-16) that
hold it in place. Save the screws.
Model 21-CET-8 Service Manual
AMPS 3
HEATER
Phase
OHMS/COIL
24.6
16.2
19.6
21.6
21.3
21.6
9.8
86.4
10.7
86.4
13.5
54
123
65
Page 17
DRYER
WIRE
OHMS
SIZE*
87
6/10
115
6/10
115
6/10
460
14
460
12
279
12
344
12
Printed 12/90