Chapter 4. Preventative Maintenance And Troubleshooting; Introduction; Maintenance Records; Daily Mainentance - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

CHAPTER 4. PREVENTATIVE MAINTENANCE AND

INTRODUCTION

MAINTENANCE RECORDS

DAILY MAINTENANCE

WEEKLY MAINTENANCE

TROUBLESHOOTING
Maintenance on the SteamCraft 3.1 must be performed on a regular basis
to keep the unit running properly. Follow the maintenance instructions in this
chapter and problems will be kept to a minimum As with any preventative
maintenance schedule, the frequency of steamer maintenance may need to
be increased, depending on equipment usage and water quality. If problems
do occur, refer to the Troubleshooting Guide in this chapter. For more
information on product and services, contact your nearest authorized
service representative. The inside rear cover of this manual lists service
centers nationwide.
Make a file solely for maintenance records. Keep a written record of daily,
weekly, monthly, and yearly maintenance. These records will protect
warranty coverage, help personnel to know when to perform various
maintenance procedures, and assist service personnel.
Blowdown Steam Generator
Blowdown the steam generator at least every four hours according to steam
generator blowdown instructions in Chapter 3.

Clean SteamCraft 3.1

Clean interior and exterior of the SteamCraft 3.1 according to shut down
instructions in Chapter 3.
Clean Drain
Steam leaks, pressure buildup in the cooking com-
partment and poor steaming performance can be caused
by a blocked drain line or screen. Blocked or slow drains
are dangerous because hot water can collect in the
compartment and spill out when opening the
compartment door.
The SteamCraft 3.1 is equipped with a drain screen in the back of the
cooking compartment. Never operate the steamer without the screen in
place. The screen prevents large food particles from entering and blocking
the drain line. Any blockage of the drain line can cause a pressure buildup in
the compartment, resulting in steam leaks around the door gasket Drain line
blockage also adversely affects convection action of the steam in the
compartment, which is necessary for optimum performance.