G. Power ON (Automatic Water Fill / Automatic Preheat)
1. Set the TIMED/MANUAL switch to timed (Dial Timer
SteamChefs) or set the selector switch to OFF (ON/OFF
control SteamChefs).
2. Turn on the utilities (if not already on).
3. Turn ON power to the SteamChef by turning the Drain Valve
Lever clockwise (down) to close the drain. See Figure 3-3.
4. The power ON indicator lights and the SteamChef reservoir fills.
5. Close the door. The SteamChef fills to the minimum
operating level and the burner ignites.
H. Lighting and Shutdown Instructions (Normal Operation and Power Failure)
1. Lighting and Shutdown Instructions for Normal Operation
Do NOT attempt to operate a SteamChef during a power failure!
DEATH, INJURY, and EQUIPMENT DAMAGE can result.
The SteamChef has an electronic ignition system, which automatically lights burners,
senses the flame, and controls gas flow. This provides precise burner control, safe
ignition, and safe shutdown.
DEATH, INJURY, OR EQUIPMENT DAMAGE may result from trying to light burners with
a flame or from an improperly adjusted gas control and ignition system. Do not try to light
burners with a flame. Do not alter any gas control adjustments.
If adjustment is required, contact a Cleveland Range authorized service center.
Cleveland Range is in no way responsible for the operation or safety of this equipment if
the controller, valve, igniter probe or any other gas system component is adjusted by
anyone other than a qualified Cleveland Range authorized service representative
The following START-UP SUMMARY is for quick reference ONLY. For safe operation and use of this
equipment, the operator must comply with all safety and operating instructions in this manual.
LIGHTING INSTRUCTIONS
1) CLOSE THE COOKING COMPARTMENT DOOR.
2) TURN THE ON/OFF LEVER/SWITCH CLOCKWISE TO THE ON POSITION.
RESERVOIR WILL FILL WITH WATER (ABOUT 1 MINUTE).
SPARK WILL INITIATE AND MAIN GAS VALVE WILL OPEN FOR 4 SECONDS.
IF THE UNIT FAILS TO LIGHT IN 4 SECONDS GAS VALVE WILL CLOSE AND LOCKOUT.
3) SYSTEM MAY BE RESET MANUALLY BY TURNING THE ON/OFF LEVER/SWITCH OFF
FOR 5 MINUTES AND BACK ON.
Follow the Power Failure Shutdown Instructions.
DO NOT TRY TO LIGHT BURNERS WITH A FLAME.
6
Figure 3-3
Drain Valve Lever