Ricoh B064 SERIES Service Manual page 391

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

[B]
[A]
B246R1097.WMF
8. Remove the by-pass feed motor [A] ( x 3,  x 1).
• At re-installation, if the tension of the belt [B] is slack, loosen the screw on the
tension bracket [C], move the screw to put more tension on the belt, then
tighten the screw at the new position.
9. Remove the by-pass unit [D] ( x 4).
When removing and installing the by-pass unit:
• Make sure that the unit does not catch on any harnesses.
• On re-installation, make sure that no harnesses are pinched between the unit
and the machine frame.
• You must re-install the by-pass unit with the duplex unit open.
SM
CÓPIA NÃO CONTROLADA
[C]
3-115
CÓPIA NÃO CONTROLADA
PAPER FEED
[D]
B246R1098.WMF
B064 Series/B140 Series
/B246 Series/D052 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents