3.6.15 TONER COLLECTION BOTTLE
1. Open the front door [A].
2. Remove the lock pin [B], then pull out the toner collection bottle [C] and its base
[D].
3. Detach the bottle from the base clamp [E] and replace it.
3.6.16 TONER SEPARATION UNIT
Development unit (
[A]: Toner separation unit ( x 3)
SM
CÓPIA NÃO CONTROLADA
[E]
3.6.1)
3-45
CÓPIA NÃO CONTROLADA
[A]
[C]
[B]
[D]
B246R959.WMF
[A]
B246R960.WMF
B064 Series/B140 Series
/B246 Series/D052 Series
DRUM UNIT