Overview - Ricoh B064 SERIES Service Manual

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

6.12 IMAGE FUSING AND PAPER EXIT

6.12.1 OVERVIEW

14
13
12
11
1. Thermistor (Center) *
2. Thermostats *
3. Thermistors *
4. Web Cleaning Unit
5. Pressure Spring
6. Entrance Guide Plate
7. Pressure Roller
8. Pressure Arm
*1
Non-contact thermistor (B064 Series only)
*2
Non-contact thermostats (B064 Series x2, B140 Series x3).
*3
Contact thermistors (B064 Series x1 end, B0140 Series x 2, end and center)
*4
B064 Series x2, B140 Series x3
*5
The D054 model only utilizes two fusing lamps.
The fusing unit is a hot roller/pressure roller system.
B064 Series
Two 550W fusing lamps switch on and off at the same time to keep the hot roller
temperature steady at 185°C.
The center thermistor (1) (not in direct contact with the hot roller) controls the
temperature at the center of the hot roller. The end thermistor (3) directly contacts
the hot roller surface and prevents overheating. The two thermostats (2) also
prevent overheating.
SM
CÓPIA NÃO CONTROLADA
15
1
16
10
9
1
2
3
6-115
CÓPIA NÃO CONTROLADA
IMAGE FUSING AND PAPER EXIT
2
3
8
B246D979.WMFF
9. Pressure Roller Cleaning Roller
10. Fusing Exit Sensor
11. Exit Junction Gate
12. Paper Exit Sensor
13. Exit Unit Entrance Sensor
14. Hot Roller Strippers
15. Hot Roller
4
16. Fusing Lamps *
*
B064 Series/B140 Series
/B246 Series/D052 Series
4
5
6
7
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents