SERVICE PROGRAM MODE TABLES
5307*
Summer Time
Lets you set the machine to adjust its date and time automatically with the change to
Daylight Savings time in the spring and back to normal time in the fall. This SP lets
you set these items:
- Day and time to go forward automatically in April.
- Day and time to go back automatically in October.
- Set the length of time to go forward and back automatically.
The settings for 002 and 003 are done with 8-digit numbers:
Digits
1st, 2nd
3rd
4th
5th, 6th
7th
8th
001
Setting
002
Rule Set (Start)
003
Rule Set (End)
5401
Access Control DFU
This SP stores the settings that limit uses access to SDK application data.
006 User Recognition – Copier
016 Use Recognition – Document Server
026 User Recognition – Fax
036 User Recognition – Scanner
046 User Recognition – Printer
076 User Recogntion – Expanded Function 1
086 User Recogntion – Expanded Function 2
096 User Recogntion – Expanded Function 2
103 Default Document ACL
Used to assign the default access privileges of users to their own documents on
the Document Server. 0:Read only (default) 1:edit 2:edit/delete 3:full control
NOTE: Available only when using Windows / LDAP / Integration Server
Authentication. Applies to new users only, it will not affect existing users.
200 SDK1 Unique ID
201 SDK1 Certification Method
210 SDK2 Unique ID
211 SDK2 Certification Method
220 SDK3 Unique ID
221 SDK3 Certification Method
B064 Series/B140 Series
/B246 Series/D052 Series
CÓPIA NÃO CONTROLADA
Meaning
Month. 4: April, 10: October (for months 1 to 9, the first digit of 0
cannot be input, so the eight-digit setting for 002 or 003 becomes
a seven-digit setting)
Day of the week. 0: Sunday, 1: Monday
The number of the week for the day selected at the 3rd digit. If " 0"
is selected for "Sunday", for example, and the selected Sunday is
the start of the 2nd week, then input a "2" for this digit.
The time when the change occurs (24-hour as hex code).
Example: 00:00 (Midnight) = 00, 01:00 (1 a.m.) = 01, and so on.
The number of hours to change the time. 1 hour: 1
If the time change is not a whole number (1.5 hours for example),
digit 8 should be 3 (30 minutes).
Enables/disables the settings for 002 and 003.
[0~1/1]
0: Disable
1: Enable
The start of summer time.
The end of summer time.
5-76
CÓPIA NÃO CONTROLADA
Rev. 01/2007
This SP codes are provided for
future customization of the access
control feature. This is to be done
at the factory, not in the field.
DFU
"SDK" is the "Software
Development Kit". This data can
be converted from SAS (VAS)
when installed or uninstalled.
DFU
SM