Ricoh B064 SERIES Service Manual page 111

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

[C]
[E]
6. Attach the ground plate [A] ( x 2) to the finisher (or the cover interposer tray).
NOTE: This is the ground with the flat plate attached with 2 vertical screws.
7. Open the front door of the finisher.
8. Pull out the lock lever [B] of the finisher ( x 1).
-or-
If the cover interposer tray is installed, pull out the lock lever of the cover
interposer tray.
9. Dock the Z-folding unit to the finisher.
10. Fasten the screw [B] ( x 1).
11. Fasten screw [E] to front lock bracket [F].
NOTE:
• Screw [E] is not needed if the Z-folder will be installed with a B246 Series
machine and the SR4000 B700 or SR970 B701.
• However, both brackets are required. Do not remove bracket
12. Fasten the rear lock bracket [D] ( x 1).
SM
CÓPIA NÃO CONTROLADA
[B]
[A]
1-71
CÓPIA NÃO CONTROLADA
Z-FOLDING UNIT (B660)
[F]
B660I013.WMF
[D]
.
B064 Series/B140 Series
/B246 Series/D052 Series