Ricoh B064 SERIES Service Manual page 735

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

4. Next, select the target destination where the debug information will be saved.
Under "5857 Save Debug Log", touch "2 Target", enter "2" with the operation
panel key to select the hard disk as the target destination, then press .
COPY : SP-5-857-002
Save Debug Log
Target (2:HDD 3:SD Card)
Initial 2
NOTE: Select "3 SD Card" to save the debug information directly to the SD
card if it is inserted in the service slot.
5. Now touch "5858" and specify the events that you want to record in the debug
log. SP5858 (Debug Save When) provides the following items for selection.
1
Engine SC Error
2
Controller SC Error
3
Any SC Error
4
Jam
NOTE: More than one event can be selected.
Example 1: To Select Items 1, 2, 4
Touch the appropriate items(s). Press "ON" for each selection. This example
shows "Engine SC Error" selected.
COPY : SP-5-858-001
Debug Save When
Engine SC Error
Example 2: To Specify an SC Code
Touch "3 Any SC Error", enter the 3-digit SC code number with the control
panel number keys, then press . This example shows an entry for SC670.
COPY : SP-5-858-001
Debug Save When
Any SC Error
NOTE: For details about SC code numbers, please refer to the SC tables in
Section "4. Troubleshooting".
SM
CÓPIA NÃO CONTROLADA
_2_
Saves data when an engine-related
SC code is generated.
Saves debug data when a controller-
related SC Code is generated.
Saves data only for the SC code that
you specify by entering code number.
Saves data for jams.
__OFF__
__ON__
__670
5-209
CÓPIA NÃO CONTROLADA
USING THE DEBUG LOG (B140/B246)
B064 Series/B140 Series
/B246 Series/D052 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents