3.7.2 DEVELOPMENT FILTER
Development unit (
[C]: Toner hopper
[D]: Filter bracket top
[E]: Filter bracket
[F]: Development filter
• Make sure that the rails where the development filter bracket [C] connects to
the development unit are clean and free of toner. If there is any toner in the
rails, wipe them clean.
• When installing a new filter, set the filter inside the filter case then place the
case on top of the filter bracket [C]. The filter case closes any gaps at the
edges of the filter to prevent toner scatter.
SM
CÓPIA NÃO CONTROLADA
3.6.1)
3-49
CÓPIA NÃO CONTROLADA
DEVELOPMENT UNIT
[A]
[D]
B246R967.WMF
B064 Series/B140 Series
/B246 Series/D052 Series
[B]
[C]