Chapter 6 Maintenance and Troubleshooting

Safety Considerations

Table 6-1. Preventive Maintenance (Continued)
Item
Cables
Inspect for pinched, worn, or
damaged cable.
Connectors
Inspect for loose or damaged
connector.
Safety Considerations
Follow your company's safety guidelines and policies when working on or around
live equipment. Refer to the National Electric Code ANSI/NFPA70, or per the
application code in the country of installation for more information.

Reading LED Conditions

In
Table
6-2, the function of each LED and its color illumination indicators are
described.
Table 6-2. LED Conditions
Indicator
Power Indicator
GPS tracking status
Alarm Indicator
88
TimeProvider 100 User's Guide
Inspection
Replace pinched, worn, or
damaged cable at the first
opportunity.
Tighten loose connectors. If
damaged, replace the connector
and the cable, or the cable at the
first opportunity.
Label
PWR
GPS
ALARM
Corrective Action
Description
Green - Power available
Off - Power not available
Green - GPS is locked
Amber - No satellite is tracked
Flashing Green - At least one satellite is
tracked
Off - No alarm is detected.
Flashing Green - The system is booting
Amber - A minor alarm.
Red - A major or critical alarm.
098-00106-000 Revision A – March, 2009
Interval
Periodically
Periodically

Advertisement