Chapter 5 CLI Commands

TimeProvider 100 CLI Command Set

Command Line Format Description
Verb – the type of action to be taken with the command.
Parameter – command input that defines the particular command element to be
shown or modified.
Data–The data input for the parameter, if any
EOL– this parser responds to any input line terminator. Possible terminators are
CR, LF, or CRLF. When the parser receives any of these terminators, the input is
terminated, and the command line entry is processed. Pressing the Enter key also
produces EOL.
Command Line Format Example
set output port2 frametype
= Verb
set
=Command
output
= Parameter
port2
frametype
TimeProvider 100 CLI Command Set
This section provides details for each of the TimeProvider 100 commands. This
section provides a description of the command followed by a series of inputs and
responses to demonstrate the correct operations and use of the command. This
series of inputs and responses for each command shows what a user can type at
the command line and the response from TimeProvider 100 for each entry typed.
The user has choices for various CLI commands. The intent of this section is to
demonstrate how each CLI command functions and how the command can be
used.
Note: When using the CLI commands, the RTE (Real Time Engine) is
referred to as "TimeMAX."

Command User Levels

The TimeProvider 100 provides a hierarchy of CLI command user levels that permit
an increasing level of access to system parameters. This hierarchy allows the
system administrator to add users who can view information only and not change
system parameters as well as add users who can view and change system
parameters.