Power Supply - Compaq ProLiant DL760 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL760:
Table of Contents

Advertisement

Power Supply

General specifications
Full output rating
Minimum load
Ambient temperature range
Operating
Storage
Input specifications
Nominal line voltage
Range input line
Frequency range
Power factor
Input power
Input current
Inrush current
Holdup time
Dielectric voltage withstand
Input to output
Input to ground
Input transient susceptibility
Common and differential mode
(superimposed on AC line)
Differential mode
Physical, Operating, and Performance Specifications 5-3
Table 5-2
Power Supply Specifications
To 40°C and 1,525 m (to 104°F and 5,000 ft)
To 32°C and 3,050 m (to 90°F and 10,000 ft) (derate
linearly)
1.0 A on + 5V output
1.0 A on + 12V output
0.5 A on + 3.3V output
10° to 40°C (50° to 104°F)
-40° to 65°C (-40° to 149°F)
Low Range/High Range
100 to 120 VAC/200 to 240 VAC
90 to 132 VAC/180 to 265 VAC
47 to 63 Hz/47 to 63 Hz
0.95/0.95
500W @ 110V/750W @ 220V
8 A at 100 VAC/10 A at 200 VAC
<70 A at 132 VAC (cold start)/<70 A at 132 VAC (cold
start)
20 ms from zero crossing at 120 VAC/20 ms from zero
crossing at 120 VAC
3000 VAC per minute/3000 VAC per minute
1500 VAC per minute/1500 VAC per minute
2500V, 10 µs pulse
20% step change in AC input voltage

Advertisement

Table of Contents
loading