System Unit - Compaq ProLiant DL760 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL760:
Table of Contents

Advertisement

5-2 Compaq ProLiant DL760 Servers Maintenance and Service Guide

System Unit

Dimensions
Height
Width
Depth
Weight (no drives and two power supplies)
Temperature range
Operating
Nonoperating
Shipping
Maximum wet bulb temperature
Input requirements (per power supply)
Rated input voltage
Rated input frequency
Rated input current
Rated input power
Power supply output power (per power supply)
Rated steady-state power
Maximum peak power
Relative humidity range (noncondensing)
Operating
Nonoperating
Heat dissipation
Maximum heat output (system is configured
to draw maximum power)
Table 5-1
System Unit Specifications
30.83 cm (12.14 inches)
48.26 cm (19.0 inches)
69.72 cm (27.45 inches)
50 kg (110 lb)
10° to 35°C (50° to 90°F)
-30° to 60°C (-20° to 140°F)
-30° to 50°C (-22° to 122°F)
38.7°C (101.7°F)
Low Range/High Range
100 to 120V/200 to 240V
47 to 63 Hz/47 to 63 Hz
8 A/10 A
740W @ 110V/1700W @ 220V
Low Range/High Range
500W/1150W
540W/1150W
20% to 80%
5% to 90%
5309 Btu/h/1555W

Advertisement

Table of Contents
loading

Table of Contents