Hot Pluggable Redundant Power Supply - Compaq ProLiant ML350 G2 Series Service Overview

Generation 2
Hide thumbs Also See for ProLiant ML350 G2 Series:
Table of Contents

Advertisement

Compaq ProLiant ML350 G2 Service Overview

Hot pluggable Redundant Power Supply

Perform the following steps to install the hot pluggable redundant power supply option:
Table 8: Hot pluggable Redundant Power Supply
Step
1.
Prepare the server for redundant power supply installation.
2.
Identify the redundant power supply bay at the back of the server.
3.
Remove the thumbscrew that secures the redundant power supply blank, and then lift the
blank form the back of the server.
4.
5.
Connect the AC power cords to the new power supply.
6.
5
See "Preparing the Server" in Chapter 3 of the Setup and Installation Guide for further preliminary teardown instruction.
Rev. 1.0
Slide the power supply into the power supply bay.
Apply pressure to the power supply until the release/lock lever clicks the power
supply securely into the bay.
Verify that the existing power supply and the redundant power supply LEDs (located
on the back of the power supplies) are green.
Action
5
21
Page 21 of 24

Advertisement

Table of Contents
loading

Table of Contents