Configuring WAN Access
Configuring IDSL connections

Example of IDSL configuration

With the following configuration, when the MAX unit receives a switched call on telephone
number 555-1212 (from a device connected to an ISDN device or a modem), the unit routes
the call to the device connected to line 1 of the IDSL card:
1
2
BRI/LT diagnostics
A MAX unit's software provides the following BRI/LT diagnostics:
BRI/LT
Line Diag
For detailed information about each parameter, see the MAX Reference.
Configuring IDSL voice-call support
The IDSL card supports incoming and outgoing voice calls. To support outgoing voice calls,
the connected Terminal Equipment (TE) must send digits to the MAX unit by means of Q.931
en-bloc dialing, that is, it sends all dialed digits to the unit in one block, the ISDN Call Setup
message, rather than one digit at a time.
The unit receives outgoing call requests from the device connected to the IDSL card and routes
voice calls to the Public Switched Telephone Network (PSTN) over a T1 line or ISDN PRI
line. The unit receives incoming voice calls on any attached T1 or PRI line, and uses Dialed
Number Identification Service (DNIS) to route the calls to devices connected to IDSL cards.
To configure IDSL voice-call support, open the System > Sys Config profile and set the
following parameters in each Line N Subprofile:
Parameter
3-44
Open a BRI/LT > Line Config profile and assign a name to it. For example:
BRI/LT
Line Config
idsl
Name=idsl
Open the Line 1 subprofile, enable the line, and assign an answer number.
Line 1...
Enabled=Yes
Dial Plan=Trunk Grp
Ans 1#=1212
Line N ...
EOC Address=0
Line LoopBack
Corrupt CRC
UnCorrupt CRC
Rq Corrupt CRC
UnRq Corrupt CRC
Clr NEBE
Clr FEBE
Sealing Current
Specifies