Configuring call routing
In the example, if the unit receives a call on channel 12 of the first line in the first slot, it places
the outgoing call on channel 11 of the first line in the first slot.
Note: The unit cannot make an outgoing call on the same channel on which it is receiving a
call. Make sure you do not configure a channel with identical channel-group and destination
channel-group numbers.

Examples of MAXDAX configuration

This section describes two MAXDAX environments, including specific parameter settings.
Routing calls on the basis of called number
Figure 3-5 shows an example of a MAXDAX installation.
Figure 3-5. Sample MAXDAX installation
On MAX 1, T1 Drop and Insert enables users connected to the PBX to make and receive calls.
The system administrator configures MAXDAX on MAX 2.
The system administrator uses Answer Plan profiles to direct incoming calls to the PRI line,
and therefore does not change any of the parameters in the Net/T1 > Line Config > Line Config
profile > Line N > Net2Net Incoming Calls profile from their default settings:
Net/T1
Line Config
3-82
Video System A
Serial line
T1
Pipeline 75
PBX
Line Config profile
Line 1...
Net2Net Incoming Calls
Ch 1=Switched
Ch 1 Dest ChanGroup=1
Ch 1 Dial Plan #=0
Ch 1 #DialPlanSelDigits=2
Ch 2=Switched
MAX
MAX
1
Leased T1
Video System B
MAX 6000/3000 Network Configuration Guide
Video System C
2
PRI
PSTN
Serial line