Limiting Calls To Unspecified Dialed Numbers - Lucent Technologies MAX 6000 Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

You can configure up to sixteen DNIS numbers with unique limiting configurations for each
DNIS number.

Limiting calls to unspecified dialed numbers

As with specified dialed numbers, you can limit the number of simultaneous modem, HDLC,
or V.110 calls. Open the Ethernet > Mod Config > DNIS Options profile, and set the following
parameters:
1
2
3
4
5
6
Examples of call routing
This section shows three sample configurations that limit incoming calls on the basis of DNIS
values.
Limiting all modem calls that do not specify a DNIS number
To specify that the MAX unit accepts ten simultaneous modem calls that do not specify a
DNIS number, set the following parameters as shown:
Limiting all calls that do not specify a DNIS number
To specify that the MAX unit accepts twenty calls, of any type, that do not specify a DNIS
number, set the following parameters as shown:
MAX 6000/3000 Network Configuration Guide
Set DNIS Limitation to Yes.
Set the Unspecified Max Calls parameter if you want to limit the total of simultaneous
V.110, HDLC, and modem calls to called numbers that do not match any specified by
DNIS #N.
Note: You must set Unspecified Max Calls even if you configure the unit to limit calls on
the basis of modem, V.110, or HDLC calls.
Set the Unspecified Max Modem parameter if you want to limit the number of
simultaneous modem calls to called numbers that do not match any specified by DNIS #N.
Set the Unspecified Max HDLC parameter if you want to limit the number of
simultaneous synchronous calls to called numbers that do not match any specified by
DNIS #N.
Set the Unspecified Max V110 parameter if you want to limit the number of simultaneous
V.110 calls to called numbers that do not match any specified by DNIS #N.
Exit the profile and, at the exit prompt, select the exit and accept option.
Unspecified Max Calls=10
Unspecified Max Modem=10
Unspecified Max HDLC=0
Unspecified Max V110=0
Unspecified Max Calls=20
Unspecified Max Modem=20
Unspecified Max HDLC=20
Unspecified Max V110=20
Configuring WAN Access