Limiting Calls To Specific Dialed Numbers - Lucent Technologies MAX 6000 Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring WAN Access
Configuring call routing
4
The unit answers the call if no maximum has been reached.
If the call does not provide DNIS information, or no specified DNIS #N value matches the
provided DNIS number:
1
2
3
4

Limiting calls to specific dialed numbers

To limit calls to specific dialed numbers, proceed as follows:
1
2
3
4
5
6
7
8
3-62
If the maximum has been reached, the unit rejects the call.
If the call is not a modem or V.110 call, the unit considers it an HDLC call and compares
the value specified for the DNIS #N Max HDLC parameter to the number of active HDLC
calls made to the called number.
If the maximum has been reached, the unit rejects the call.
The MAX unit compares the value specified for the Unspecified Max Calls parameter to
the number of unspecified active calls.
If the maximum has been reached, the MAX rejects the call.
If the call is a modem call, the unit compares the value specified for the Unspecified Max
Modem parameter to the number of unspecified active modem calls.
If the maximum has been reached, the unit rejects the call.
If the call is a V.110 call, the unit compares the Unspecified Max V110 parameter to the
number of unspecified active V.110 calls.
If the maximum has been reached, the unit rejects the call.
If the call is not a modem or V.110 call, the unit considers it an HDLC call and compares
the value specified for the Unspecified Max HDLC parameter to the number of
unspecified active HDLC calls.
If the maximum has been reached, the unit rejects the call.
The unit answers the call if no maximum has been reached.
Open the Ethernet > Mod Config > DNIS Options profile.
Set DNIS Limitation to Yes.
Set the DNIS #N parameter to a called number.
The MAX unit compares the called number to the DNIS #N value digit-by-digit, from
right to left. A match occurs if all the digits specified by DNIS #N match the digits at the
end of the called number. For example, if you set DNIS #N to 1235, the called number
8761235 matches, but 8762235 does not match.
Set the DNIS #N Max Calls parameter to specify the total number of simultaneous V.110,
HDLC, and modem calls to the called number specified by DNIS #N.
Note: You must set the DNIS #N Max Calls parameter even if you configure the unit to
limit calls on the basis of modem, V.110, or HDLC calls.
Set DNIS #N Max Modem if you want to limit the number of simultaneous modem calls
to the called number specified by DNIS #N.
Set DNIS #N Max HDLC if you want to limit the number of simultaneous synchronous
calls to the called number specified by DNIS #N.
Set DNIS #N Max V110 if you want to limit the number of simultaneous V.110 calls to the
called number specified by DNIS #N.
Exit the profile and, at the exit prompt, select the exit and accept option.