Configuring Individual WAN Connections

Configuring MP, MP+ and BACP connections

tommy Password = "localpw"

Enabling PPP dial-out for V.110 modems

The MAX unit can make outgoing calls to a V.110 terminal-adapter client by means of using
the PPP protocol. This feature also supports the callback feature via V.110 for the MAXLink
Client software product. For information about enabling dial-out through the unit's digital
modems, see "Configuring dial-out options" on page 4-89.
To enable PPP dial-out for V.110 modems:
1
2
3
In the Data Svc settings, V.110 is the V.110 indicator, which tells the unit to communicate with
a V.110 terminal adapter (through the V.110 modem).
In this case, the connection to the remote terminal adapter (TA) uses a bit rate of 19.2 Kbps
over a line using the Switched-56 data service. If the unit cannot sync up with the remote TA at
the specified bit rate, it attempts to use one of the other bit rates. (For more detailed
information about the Data Svc parameter, see the MAX Reference.)
Configuring MP, MP+ and BACP connections
MP uses the encapsulation defined in RFC 1717. It enables the MAX unit to interact with
MP-compliant equipment from other vendors to use multiple channels for a call. MP
parameters include the PPP parameters described in "PPP Options" on page 4-7. MP without
BACP requires setting a few additional parameters. If you use MP with BACP, you have to set
a greater number of additional parameters. Following are the additional parameters required
for MP without BACP:
Ethernet
Answer
Ethernet
Connections
4-46
Service-Type = Framed-User,
Framed-Protocol = PPP,
Framed-IP-Address = 10.2.3.31,
Framed-IP-Netmask = 255.255.255.0
Open the Connection profile configured for asynchronous PPP.
Open the Telco Options subprofile and specify the following data service:
Ethernet
Connections
Connection profile
Telco Options
Data Svc=v110 19.2 56K
Exit the profile and, at the exit prompt, select the exit and accept option.
Encaps
MP=Yes
PPP=Yes
PPP Options
Min Ch Count=1
Max Ch Count=1