Example Of Immediate-Mode Configuration - Lucent Technologies MAX 6000 Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Example of immediate-mode configuration

To configure immediate Telnet service relying on the Telnet host for authentication:
1
2
3
4
5
6
Following is an example of this configuration:
Ethernet
Mod Config
Configuring menu mode
You can set up the terminal server to display a menu of up to four Telnet hosts that dial-in users
can select for logging in. You can set up menu mode with the following parameters in
Ethernet > Mod Config > TServ Options:
Parameter
Initial Scrn
Toggle Scrn
Remote Conf
Host #N Addr
Host #N Text
Example of menu-mode configuration
Configuration of this example enables the menu to appear at login, and specifies four hosts.
The user does not have access to the command line. To implement the configuration:
1
2
MAX 6000/3000 Network Configuration Guide
Open Ethernet > Mod Config > TServ Options.
Set the Immed Service parameter to Telnet.
Specify the name or IP address of the Telnet host.
If appropriate, specify the TCP port to use on the Telnet host.
Set the Telnet Host Auth parameter to Yes.
Exit the profile and, at the exit prompt, select the exit and accept option.
TServ Options
Immed Service=Telnet
Immed Host=host1.abc.com
Immed Port=23
Telnet Host Auth=Yes
Specifies
Whether or not the terminal server brings up a menu interface first for
interactive users initiating connections.
Whether users can switch to the command-line interface from menu
mode and vice versa.
That the RADIUS server supplies the terminal-server menu and list of
hosts.
An IP address for up to four Telnet hosts that appear in the menu
interface.
A hostname for up to four Telnet hosts that appear in the menu
interface.
Open the Ethernet > Mod Config > TServ Options profile.
Specify that the dial-in users are in menu mode initially:
Ethernet
Mod Config
TServ Options
Initial Scrn=Menu
Configuring Individual WAN Connections
Configuring terminal-server connections
4-87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents