Example of dial-out configuration

The configuration in this example enables direct access (immediate modem) on port 5000. To
implement the configuration:
1
2
3
4

Configuring a Combinet connection

The MAX unit supports Combinet bridging to link two LANs as if they were one segment. For
a Combinet connection to work, bridging must be enabled at the system level (as described in
Chapter 13, "Configuring Packet Bridging.") Figure 4-16 shows a Combinet connection.
Figure 4-16. A Combinet connection
Combinet configuration involves the following parameters: (shown with sample settings)
Ethernet
Mod Config
Ethernet
Answer
MAX 6000/3000 Network Configuration Guide
Open the Ethernet > Mod Config > TServ Options profile.
Enable the use of the modem dial-out and direct-access (immediate-modem) features. For
example:
Ethernet
Mod Config
TServ Options
Modem dialout=Yes
Immediate Modem=Yes
Specify the port on which the immediate-modem feature functions, and specify a
password for modem access. For example:
Ethernet
Mod Config
TServ Options
Imm. Modem port=5000
Imm. Modem Pwd=dialoutpwd
Exit the profile and, at the exit prompt, select the exit and accept option.
MAX
Bridging=Yes
Encaps
COMB=Yes
COMB Options
Password Reqd=Yes
Interval=10
Compression=Yes
Configuring Individual WAN Connections