Configuring Individual WAN Connections
The Connection profile
Encaps Type
The Encaps Type parameter specifies which encapsulation to use when calling the remote IP
network across X.25.
Max Unsucc. Calls
The Max Unsucc. Calls parameter specifies the maximum number of unsuccessful X.25 calls
the unit tries to place before dropping the modem connection.
Inactivity Timer
The Inactivity Timer parameter specifies the number of seconds to allow a connection to
remain inactive before dropping the virtual circuit.
Call Mode
The Call Mode parameter specifies whether or not the unit can initiate a call request on the
X.25 IP connection.
Answer X.121 Addr
The Answer X.121 Addr parameter specifies the X.121 address of the remote X.25 host to
which this profile connects. The remote host is assumed to support RFC1356 encapsulation of
IP packets.
Remote X.121 Addr
The Remote X.121 Address parameter specifies the X.121 address of the remote X.25 host to
which this profile connects. The remote host is assumed to support RFC1356 encapsulation of
IP packets.

Encaps=X.32

When Connections > Connection profile > Encaps=X.32, the parameter appears in the
interface for Ethernet > Connections > Connection profile > Encaps Options. This X.25 Prof
parameter specifies the name of an X.25 profile to use for this connection. To guard against
misconfiguration, the MAX unit does not allow you to save an active Connection profile
specifying X.25 encapsulation unless the named X.25 profile is defined and active.
Encaps=TCP-Clear
When Connections > Connection profile > Encaps=TCP-Clear, the following parameters
appear in the interface for Ethernet > Connections > Connection profile > Encaps Options:
Ethernet
Connections
4-28
Connection profile
Recv PW=
Login Host=
Login Port=0
Detect End of Packet=
MAX 6000/3000 Network Configuration Guide