Figure 4-3 An Mp+ Connection; Example Of Mp+ Configuration - Lucent Technologies MAX 6000 Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring Individual WAN Connections
Configuring MP, MP+ and BACP connections
Attribute
Ascend-Dec-Channel-
Count (237)
Ascend-Seconds-Of-
History (238)
Ascend-Add-Seconds
(240)
Ascend-Remove-Seconds
(241)
Ascend-Target-Util (234) Percentage of line utilization (default 70%) to use as a threshold
Ascend-Maximum-
Channels (235)
Note: If a RADIUS profile does not specify Ascend-Maximum-Channels, the default value
of 1 prevents the client from establishing a multichannel call.

Example of MP+ configuration

Figure 4-3 shows the MAX unit connected to a remote Pipeline unit with an MP+ connection.
Figure 4-3. An MP+ connection
To configure an MP+ connection with a remote MAX unit:
1
2
3
4-54
Value
Number of channels the MAX can subtract at one time, dropping
the newest channels first.
Number of seconds to use as the basis for calculating average line
utilization (ALU).
Number of seconds for which ALU must persist beyond the
Target-Utilization threshold before the MAX adds bandwidth.
Number of seconds for which the ALU must persist below the
Target-Utilization threshold before the unit subtracts bandwidth.
when determining when to add or subtract bandwidth.
Maximum number of channels available to a multilink PPP
connection. In this release, MP does not make use this value.
However, it's value does apply to MP+ connections.
MAX
Open the Answer profile.
Set PPP and MP+ encapsulation to Yes and specify the appropriate routing, bridging, and
authentication values. For example:
Ethernet
Answer
Encaps
MPP=Yes
PPP=Yes
PPP Options
Route IP=Yes
Route IPX=No
Bridge=No
Recv Auth=Either
Exit the profile and, at the exit prompt, select the exit and accept option.
WAN
Pipeline 25
MAX 6000/3000 Network Configuration Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents