The Combinet Bridging Parameters - Lucent Technologies MAX 6000 Configuration Manual

Hide thumbs Also See for MAX 6000:
Table of Contents

Advertisement

Configuring Individual WAN Connections
Configuring a Combinet connection
Ethernet
Connections

The Combinet bridging parameters

This section provides some background information about a Combinet configuration.
Specifying the hardware address of the remote Combinet bridge
The (Connection profile) Station parameter must specify the MAC address of the remote
Combinet bridging device.
Enabling bridging
A Combinet connection is always a bridging connection, so the Bridge parameter in the
Connection profile must be set to Yes. If the Bridge parameter is N/A, bridging has not been
enabled in the Ethernet profile (as described in Chapter 13, "Configuring Packet Bridging").
Requiring a password from the remote bridge
You can specify that an individual Combinet connection does not require a password
exchange, even if the Answer profile specifies that Combinet passwords are required.
Specifying passwords to exchange with the remote bridge
The Send PW parameter specifies the password sent to the remote device. It must match the
password expected from the MAX unit. The Recv PW parameter specifies the password sent to
the unit from the remote device.
Configuring line-integrity monitoring
The (Answer profile) Interval parameter specifies the number of seconds between
transmissions of Combinet line-integrity packets. You can specify a number between 5 and 50.
If the MAX unit does not receive a Combinet line-integrity packet within the specified
interval, it disconnects the call.
Base channel count
The (Connection profile) Base Ch Count parameter specifies the base number of channels to
use when setting up the call. It can be set to 1 (for 64 Kbps) or 2 (for 128 Kbps).
4-92
000145CFCF01
Station=000145CFCF01
Encaps=COMB
Bridge=Yes
Encaps Options
Password Reqd=Yes
Send PW=remotepw
Recv PW=localpw
Interval=10
Base Ch Count=2
Compression=Yes
MAX 6000/3000 Network Configuration Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Max 3000

Table of Contents