SP7-xxx: Data Log-2
Transfer(Page)
002
Sets the PM yield of the transfer unit (Pages).
Fuser(Page)
003
Sets the PM yield of the fusing unit (Pages).
Developer(Page)
004
Sets the PM yield of the developer (Pages).
PCD(Rotation)
005
Sets the PM yield of the PCD (Rotations).
Transfer(Rotation)
006
Sets the PM yield of the transfer unit (Rotations).
Fuser(Rotation)
007
Sets the PM yield of the fusing unit (Rotations).
Developer(Rotation)
008
Sets the PM yield of the developer (Rotations).
Web (%)
009
Sets the PM yield (%) of the web unit.
PCD (Day Threshold)
010
Sets the PM yield (day threshold) of the PCD.
Transfer (Day Threshold)
011
Sets the PM yield (day threshold) of the transfer unit.
Fuser (Day Threshold)
012
Sets the PM yield (day threshold) of the fusing unit.
013 Web (%)
D009/D011/D012/D013
[0 to 9999999 / 160000 / 1 sheet]
[0 to 9999999 / 160000 / 1 sheet]
[0 to 9999999 / 320000 / 1 sheet]
[0 to 999999999 / 199000 / 1 mm]
[0 to 999999999 / 277000 / 1 mm]
[0 to 999999999 / 54880000 / 1 mm]
[0 to 999999999 / 125530000 / 1 mm]
[0 to 255 / 92 / 1 %]
[1 to 30 / 15 / 1 day]
[1 to 30 / 15 / 1 day]
[1 to 30 / 15 / 1 day]
[1 to 30 / 15 / 1 day]
5-168