019 Waiting Time: Low: Thick 2
020 Waiting Time: Low: Thin
021 Waiting Time: Medium: Plain
022 Waiting Time: Medium: M-Thick
023 Waiting Time: Medium: Thick 1
024 Waiting Time: Medium: Thick 2
025 Waiting Time: Medium: Thin
026 Temp.: Low: Plain
027 Temp.: Low: Plain
028 Temp.: Low: Thick 1
029 Temp.: Low: Thick 2
030 Temp.: Low: Thin
031 Temp.: Medium: Plain
032 Temp.: Medium: M-Thick
033 Temp.: Medium: Thick 1
034 Temp.: Medium: Thick 2
035 Temp.: Medium: Thin
036 CPM: Low: Plain
037 CPM: Low: M-Thick
SM
CPM down mode is activated or not
after the time specified with these SPs
has passed.
Adjusts the threshold temperature of
the fusing unit to enter the CPM down
mode.
[100 to 200 / 120 / 1 deg]
If the temperature of the fusing unit is
less than the temperature specified
with these SPs, the machine changes
the CPM (adjustable with SP1916-36
to -45).
Adjusts the CPM in the CPM down
mode.
C1b: [20 to 35 / 35 / 5 cpm]
C1c: [20 to 45 / 45 / 5 cpm]
Adjusts the CPM in the CPM down
mode.
C1b: [20 to 35 / 35 / 5 cpm]
C1c: [20 to 45 / 45 / 5 cpm]
5-17
SP1-xxx: Feed-3
D009/D011/D012/D013