The supplied voltage is not sufficient due to a defective communication line
or defective connection.
Same as -001
Consult with the user's local telephone company.
Incorrect network setting
Both the NIC and Embedded RCG-M are activated at the same time.
-011
-
Same as -001
Disable the NIC with SP5985-1.
Modem board error
The modem board does not work properly even though the setting of the
modem board is installed with a dial up connection.
-012
-
Same as -001
1.
Install the modem board.
2.
Check and reset the modem board setting with SP5816.
3.
Replace the modem board.
Incorrect dial up connection
-001: Program parameter error
-002: Program execution error
651
C
An unexpected error occurs when the modem (Embedded RCG-M) tries to
call the center with a dial up connection.
Caused by a software bug
Engine startup error
The BICU fails to respond with the prescribed time when the machine is
670
D
turned on.
Connections between BICU and controller board are loose,