Ricoh D009 Service Manual page 107

Hide thumbs Also See for D009:
Table of Contents

Advertisement

4.
Turn the SD-card label face [2] to the rear of the machine. Then push it slowly into slot 1
until you hear a click.
5.
Connect the network cable if it needs to be connected.
6.
Turn on the main power switch.
7.
Go into the SP mode and push "EXECUTE" with SP5-878-001.
8.
Exit the SP mode and turn off the operation switch. Then turn off the main power switch.
9.
Turn on the machine power.
10. Do SP5990-005 (SP print mode Diagnostic Report).
11. Make sure the ROM number and firmware version in area [a] of the diagnostic report
are the same as those in area [b].
[a]: "ROM Number/Firmware Version" – "HDD Format Option"
[b]: "Loading Program" – "GW2a_zoffy"
Diagnostic Report:
DataOverwriteSecurity
Unit
The ROM number and firmware version number change when the firmware is
upgraded. However, the important thing is to make sure the numbers in [a] are
the same as the numbers in [b].
If the ROM numbers are not the same, or the version numbers are not the same,
this means the unit was not installed correctly.
If this happens:
Make sure of the unit type (must be Type I).
If they do not match:
1) Replace the NV-RAM on the controller.
2) Replace the "DataOverwriteSecurity Unit" (SD card) with the correct type
3) Do the installation procedure in this procedure again, from Step 1.
12. Go into the User Tools mode, and select System Settings> Administrator Tools> Auto
Erase Memory Setting> On.
13. Exit the User Tools mode.
SM
DataOverwriteSecurity Unit Type I (D362)
"ROM No. / Firmware
Version" [a]
HDD Format Option:
D3775912 / 1.00m
1-73
"Loading Program" [b]
GW2a_zoffy:
D3775912 / 1.00m
D009/D011/D012/D013

Advertisement

Table of Contents
loading

This manual is also suitable for:

D011D012D013

Table of Contents