Never touch the drum surface with bare hands.
Re-installation
1.
Replace the drum and close the PCDU (
2.
Put the opening cap [A in the previous procedure] back in its original place.
3.
Detach the spring [A] from
You must re-attach the spring to ,
If you fail to re-attach the spring to
contact the drum for cleaning, but the machine will operate without generating
an error. However, copies will gradually become dirty due to toner collecting on
the drum.
4.
Re-attach the spring on the rear side of the PCDU.
5.
After replacing the drum, do these SPs:
SP 2001: Drum charge roller voltage – make sure that this is at the default setting
SP 3001-2: ID sensor initial setting
SP 2805: Process initial setting
SP 2810-1: Grayscale Setting
SM
x 2).
,
and re-attach it to
,
for the cleaning blade to operate correctly.
and , the movable cleaning blade will not
3-31
.