Perform Quick Test again to verify the adjustment. Check the page to see if the image on the page is still
6.
skewed. If it is, repeat the adjustment.

Sensor Tests

There are two groups of sensors tests, static sensors and dynamic sensors.
To run the Sensor Test:
Touch SENSOR TESTS from the Diagnostics Menu.
1.
2.
Select either Static Sensors or Dynamic Sensors.
For static sensors—view the current status. Exit menus and enter the menus again to change the
state.
For dynamic sensors—view the current status and toggle the state to test the sensor.
Press
to exit a test.
Sensor type
Static sensors
Service Manual
3-18
Sensor name
Possible values
Waste Toner
Empty, Full, or
Missing
Belt Waste
Empty or
percentage full
Fuser Temp
Degrees (C)
BUR Temp
Degrees (C)
Power
Voltage
Sensor activation
N/A
N/A
N/A
N/A
N/A
Previous
Next
Go Back