4 Replacement Procedures
Installing the Cover assembly and Base assembly
The following describes the procedure for installing the cover assembly and base assembly.
(See Figure 4-24 and 4-25.)
1. Install the cover assembly on the base assembly.
2. Connect the LCD cable, speaker cable, switch cable and finger print sensor cable
to the connector CN5000, CN6170, CN9500 and CN9550 on the system board.
3. Secure the cover assembly and base assembly with the following screws.
• M2×4B
• M2.5×8B
4. Close the display and turn over the computer.
5. Secure the cover assembly and base assembly with the following screws.
• M2.5×8B
• M2.5×16B
4-38
[CONFIDENTIAL]
BIND screw
FLAT HEAD screw
FLAT HEAD screw
FLAT HEAD screw
4.14 Cover assembly and Base assembly
×1
×1
×3 ("8" in the figure 4-24)
×6 ("16" in the figure 4-24)
TECRA M9 Maintenance Manual (960-631)