Mitsubishi QJ71C24/-R2 User Manual page 75

Melsec system q programmable logic controllers, serial communication modules gx configurator-sc
Hide thumbs Also See for QJ71C24/-R2:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
597
613
(255
)
(265
)
H
H
598
614
(256
)
(266
)
H
H
For confirmation
599
615
of communica-
(257
)
(267
)
H
H
tion result
600
616
(258
)
(268
)
H
H
601
617
(259
)
(269
)
H
H
602
618
(25A
)
(26A
)
H
H
603
619
(25B
)
(26B
)
H
H
604 to
620 to
607
1023
Use prohibited
(25C
(26C
to
H
H
to 25F
)
3FF
)
H
H
1024
2048
(400
)
(800
)
H
H
1025 to
2049 to
1535
2559
(401
to
(801
to
H
H
Transmission/rece
5FF
)
9FF
)
H
H
ive area
1536
2560
(600
)
(A00
)
H
H
1537 to
2561 to
2047
3071
(601
to
(A01
to
H
H
7FF
)
BFF
)
H
H
3072 to 6911
For user
(C00
to 1AFF
)
H
H
6912to 6952
(1B00
to 1B28
)
H
H
6953 to 6993
(1B29
to 1B51
)
H
H
6994 to 7034
(1B52
to 1B7A
)
H
H
7035 to 7075
(1B7B
to 1BA3
)
H
H
7076 to 7116
(1BA4
to 1BCC
)
H
H
7117 to 7157
(1BCD
to 1BF5
)
H
H
7158 to 7198
(1BF6
to 1C1E
)
H
H
7199 to 7239
(1C1F
to 1C47
)
H
H
7240 to 7280
(1C48
to 1C70
)
H
H
7281 to 7321
(1C71
to 1C99
)
H
H
7322 to 7362
(1C9A
to 1CC2
)
H
H
7363 to 7403
(1CC3
to 1CEB
)
H
H
7404 to 7444
(1CEC
to 1D14
)
H
H
7445 to 7485
(1D15
to 1D3D
)
H
H
3 - 25
Name
Transmission sequence status (For confirmation of MC protocol
communication status)
0: Waiting for receiving command
1: Receiving command
2: Command reception complete
3: Waiting to access PLC CPU
4: Accessing PLC CPU
5: PLC CPU access complete
6: Response message transmission
On-demand execution result
0
: Normal completion
1 or more: Abnormal completion (error code)
Data transmission result
0
: Normal completion
1 or more: Abnormal completion (error code)
Data reception result
0
: Normal completion
1 or more: Abnormal completion (error code)
System area
MC protocol transmission error code
(excludes A compatible 1C frame communication)
0: No error
1 or more: Transmission error code
Receive user frame (nth)
0
: Not received
1 to 4: Combination of user frame No. designations for reception
message
System area
Transmission data count designation
0: No designation
1 or more: Number of send data
Transmission data designation
Data to be sent to an external device
Receive data count (Number of data for which read is requested)
0: No receive data
1 or more: Number of receive data
Receive data
Data received from an external device
User free area (3840 words)
Determined by the user.
For registration No. 8001
H
For registration No. 8002
H
For registration No. 8003
The user registration area has the following combined uses, with
H
data written by the user according to the purpose of use by the
For registration No. 8004
H
TO instruction, etc.
See each explanation item concerning the configuration of each
For registration No. 8005
H
area, the data written, etc.
For registration No. 8006
H
(1) If data communications is being carried out by user
registration frame.
For registration No. 8007
H
• User registration frame (User's Manual (Application),
For registration No. 8008
H
(2) If data communications is being carried out by the modem
For registration No. 8009
H
function.
For registration No. 800A
H
• Initialization Data (User's Manual (Application) Section
For registration No. 800B
H
• Connection Data (User's Manual (Application) Section
For registration No. 800C
H
For registration No. 800D
H
For registration No. 800E
H
Chapter 9)
3.4.3)
3.4.4)
MELSEC-Q
Applicable
Registration
Initial
protocol
allowed/not
value
allowed
MC Non Bi
R
Not allowed
0
RW
RW
RW
Not allowed
0
R
0
RW
Not allowed
0
RW
Not allowed
Not allowed
Reference
section
Section
8.6.4
Section
10.1.4
Chapter 6
Chapter 7
Section
8.6.5
Section
8.6.6
Section
8.6.4
Section
8.6.5
Chapter 6
Chapter 7
Section
8.4.5
Section
8.4.7
Refer to left
description
3 - 25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24nSh-080007Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2 ... Show all

Table of Contents