3 SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
182
342
User frame being
(B6
)
(156
)
transmitted
H
H
183
343
(B7
)
(157
)
H
H
184
344
(B8
)
(158
)
For user frame
H
H
being transmitted
185
345
designation
(B9
)
(159
)
H
H
186 to
346 to
285
445
(BA
to
(15A
to
H
H
11D
)
1BD
)
H
H
For designation
286
446
of transmission
(11E
)
(1BE
)
H
H
wait time
287
447
(1BF
)
(11F
)
H
H
For designation
of transparent
code
288
448
(1C0
)
(120
)
H
H
289
449
For conversion
(121
)
(1C1
)
designation
H
H
290 to
450 to
303
511
Use prohibited
(122
to
(1C2
to
H
H
12F
)
1EF
)
H
H
For confirmation
512
of station No.
(200
)
H
setting status
513
(201
)
H
For confirmation
of LED ON status
and
communication
error status
514
(202
)
H
3 - 22
Name
User frame being transmitted
0
: Not send
1 to 100: User frame being transmitted (nth)
CR/LF output designation
0: Do not send.
Output head pointer designation
0: No designation
Output count designation
0: No designation
Output frame No. designation (A maximum of 100 can be specified)
Message wait time designation
0: No wait time
Transmission transparent code designation 1st
0000
: No designation
H
Other than 0000
: Designated (below)
H
• Transparent code (b0 to b7)
00
to FF
: Transparent code
H
H
• Additional code (b8 to b15)
00
to FF
: Additional code
H
H
Receive transparent code designation
0000
: No designation
H
Other than 0000
: Designated (below)
H
• Transparent code (b0 to b7)
00
to FF
: Transparent code
H
H
• Additional code (b8 to b15)
00
to FF
: Additional code
H
H
ASCII-BIN conversion designation
0: No conversion
System area
Station No. (switch setting)
LED ON status and communication error status on CH1 side
0: Turned off/OFF, no error
SD WAIT (b0)
SIO
(b1)
PRO.
(b2)
P/S
(b3)
For system (b8) to (b15)
LED ON status and communication error status on CH2 side
0: Turned off/OFF, no error
SD WAIT (b0)
SIO
(b1)
PRO.
(b2)
P/S
(b3)
C/N
(b4)
For system (b8) to (b13)
1: Send.
1 to 100: Send from nth
1 to 100: Output n
1
to F
: Wait time (unit: 10 ms)
H
H
1: Convert
1: Turned on/ON, error
C/N
(b4)
NAK (b5)
ACK. (b6)
NEU. (b7)
1: Turned on/ON, error
NAK
(b5)
ACK.
(b6)
NEU.
(b7)
CH2.ERR. (b14)
CH1 ERR. (b15)
MELSEC-Q
Applicable
Registration
Initial
protocol
allowed/not
value
allowed
MC Non Bi
0
R
Not allowed
0
RW
Allowed
RW
0
Allowed
RW
Depends
on
parame-
ter setting
R
Not allowed
Depends
on
module
status
Reference
section
Section
8.4.7
Chapters 9
and 11 of
User's
Manual
(Application)
Section
8.4.6
Section
8.4.5
Chapter 12
of User's
Manual
(Application)
Section 4.3
Section
4.5.2
Section
8.6.9
3 - 22