Mitsubishi QJ71C24/-R2 User Manual page 301

Melsec system q programmable logic controllers, serial communication modules gx configurator-sc
Hide thumbs Also See for QJ71C24/-R2:
Table of Contents

Advertisement

APPENDIX
Accessing other stations with link dedicated instructions
Interrupt processing
(at data reception)
Communication via public lines using modem function
Communication using the PLC CPU monitoring function
Auto refresh directed to the PLC CPU
Transmission control
Half-duplex communication control
Mode switching
Independent operation of two
interfaces
Linked operation of two interfaces
Registering initial setting values of the buffer memory
Registering user frame
Connection forms with external
devices
I/O signal transmission/receive by multi drop link function
Connection of GX Developer
Communication data monitoring
Registering and monitoring of setting values by the utility package
PLC that can be mounted
Data transmission rate (bps)
1 Access is possible only within the range of an AnACPU device.
2 A multiple block batch read/write function can be used for the local station QCPU to which the Q series
C24 is mounted and the next CPU module, which will be another station, via MELSECNET/H,
MELSECNET/10.
Function
Multiple block batch read/write
This function is added to modules showing 9707B or later in the package indication and the DATE
column of the rating plate.
3 Access to other stations cannot be performed via data link system (MELSECNET(II), MELSECNET/B).
4 Transmission is only possible using the printer function.
5 When the Q series C24 is used, it is possible to read/write a maximum of 960 words (in case of QC24(N), it
is possible to read/write a maximum of 480 words.)
6 230400 bps can be used via CH1 of QJ71C24N (-R2/R4) only.
The maximum transmission speed of QJ71C24 (-R2) is 115200 bps.
App. - 7
Function
Non procedure protocol
Bidirectional protocol
DC code control
DTR/DSR signal control
Setting the same protocol
Setting different protocols
1:1, 1:n
m:n
QCPU
(All allowed)
Q series C24
(Flash ROM)
QCPU
MELSECNET/H
remote I/O station
230400 maximum
( 6)
PLC CPU
QnACPU
Q2AS(H)
(9707B or later products)
MELSEC-Q
QC24N
QC24
UC24
(via QC24 (N))
(EEPROM)
ACPU
QnACPU
AnACPU
MELSECNET/10,
AnUCPU
Remote I/O station
QnACPU
115200
19200
19200
maximum
maximum
maximum
: Function exists/possible
: Function exists/possible
(specification is different
depends on the function
version (see Appendix 1)
: No function/impossible
Q4AR
(All allowed)
C24-S8
ACPU
AnACPU
AnUCPU
QnACPU
19200
maximum
App. - 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24nSh-080007Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2 ... Show all

Table of Contents