3 SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
For confirmation
515
of switch setting
(203
)
and mode
H
switching
516
(204
)
H
517 to 541
(205
to 21D
)
H
H
For confirmation
of user frame
542
(51E
)
H
543
Use prohibited
(51F
)
H
For confirmation
544
of flash ROM
(220
)
H
write result
545
(221
)
H
546
(222
)
H
For confirmation
of modem
function
547
(223
)
H
548 to 549
(224
to 225
)
H
H
550
(226
)
H
3 - 23
Name
Switch setting error and mode switching error status
0: No error
Other than 0: Switch setting error and mode switching error
CH1 Communication protocol setting No. (b0)
CH1 Communication rate setting (b1)
CH1 Setting change prohibit time mode switching (b3)
CH2 Communication protocol setting No. (b4)
CH2 Communication rate setting (b5)
CH2 Setting change prohibit time mode switching (b7)
Setting station No. (b14)
Linked operation setting (b15)
Number of registered user frames
0
: No registration
1 or more: Number of registered frames
H
User frame registration status (for confirmation of registration No.)
0: No registration
Bit corresponding to registration No. is 0(ON)/1(OFF).
Registration No.3E8
(1000) : Address 205
H
Registration No. 4AF
(1199) : Address 211
H
Number of registered default registration frames (for system)
System area
Flash ROM system parameters write result
0
: Normal completion
Other than 1 (error code) : Abnormal completion
Modem function error code (error code when modem function is
being used)
0
: Normal completion
Other than 1 (error code) : Abnormal completion
Modem function sequence status
0: Idle
7: Modem disconnected
1: Waiting for initialization
8: Callback Request reception waiting
2: Initializing modem
9: Callback Modem disconnect waiting
3: Waiting
10: Callback Delay time waiting
4: Checking password
11: Callback Reconnecting
5: Communicating
12: Callback Rechecking password
6: Notification in progress
Number of data registration for connection
0: No registration
Data registration status for connection
(for confirmation of registration No.)
0: No registration
Bit corresponding to registration No. is 0(ON)/1(OFF).
Registration No. BB8
(3000) : Address 224
H
Registration No. BD5
(3029) : Address 225
H
Number of data registration for initialization
0: No registration
0: Normal
1: Error
0: Normal
1: Error
0: Normal
1: Error
0: Normal
1: Error
0: Normal
1: Error
0: Normal
1: Disable
0: Normal
1: Out of range
0: Normal
1: Error
1: Registered
(b0) to
H
(b7)
H
1 or more: Number of registration
1: Registered
(b0) to
H
(b13)
H
1 or more: Number of registrations
MELSEC-Q
Applicable
Registration
Initial
protocol
allowed/not
value
allowed
MC Non Bi
0
R
Not allowed
Depends
on
R
Not allowed
registration
status
RW
Not allowed
0
R
Not allowed
Reference
section
Section 4.3
Section
4.5.2
Section
8.6.9
Section
8.6.9
Section
8.6.9
Section
9.1.2 of
User's
Manual
(Application)
Section
8.6.9
Section
8.6.2
Chapter 3
of User's
Manual
(Application)
3 - 23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24nSh-080007Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2 ... Show all