INSTALLATION PROCEDURE

[A]
2. Remove the left scale [A] (2 screws).
3. Place the DF exposure glass [B] on the glass holder.
NOTE: When installing the DF exposure glass, make sure that the white point
[C] is positioned at the lower front side, as shown.
4. Peel off the backing [D] of the double-sided tape attached to the rear side of the
scale guide [E], then install the scale guide (2 screws removed in step 2).
5. Install the two stud screws [F].
6. Mount the DF by aligning the holes [G] in the DF with the stud screws, then
slide the DF to the front as shown.
7. Secure the DF unit with two screws [H].
C264
[E]
[D]
[B]
1-14
[H]
[G]
[F]
[C]
C264